Trans Energy Solutions

Nodalus Software

Engineering software for power and traction networks, built in South Africa. Draw the network, run the studies and produce the reports, on your own Windows PC.

Download the installer Why Nodalus See the features
Nodalus Power Flow showing a 132/66/33/11 kV single-line diagram with load flow results and a results table

Easy To Use Drag-And-Drop User Interface

Two products, one suite

Nodalus Power Flow

A single-line-diagram editor and study suite for transmission, distribution and industrial networks.

View Power Flow features →

Nodalus Traction Power Simulator (TPS)

Railway electrification studies for 3 kV DC and 25 kV AC systems: trains, substations, overhead line and protection.

View TPS features →
Why Nodalus
Built for the studies engineers actually run

One desktop suite for network studies and railway power, made in South Africa and supported by the people who wrote it.

1Your data stays with you

  • Runs on your own Windows PC
  • Network models and results are not uploaded to a cloud service
  • No browser account to manage

2Power and traction together

  • Network studies and railway electrification in one installer
  • Import a train run into a network study as a time-varying load
  • Rare in a single package

3Studies beyond load flow

  • Protection, harmonics, motor starting and transient stability
  • Compensation, FACTS, earth grid design and DC auxiliary systems
  • One diagram feeds every study

4Methods you can follow

  • Studies follow published methods, such as IEC 60909 for short circuit
  • Results appear on the diagram and in tables you can export
  • CSV and report export from the result windows

5Local support

  • South African company with local contact by phone and email
  • Questions answered by the engineers behind the software
  • Licensing and invoicing in South Africa

6Simple to start

  • One installer, drag-and-drop diagram
  • Try the full software free for 7 days
  • Licence per computer, with a volume quote for teams
Nodalus Power Flow
Network studies from one diagram

Draw a single-line diagram, enter the equipment data, and run the studies below. Results are shown on the diagram and in tables, and can be exported to CSV or a report.

1Diagram editor

  • Drag-and-drop single-line diagram
  • Buses, lines, cables, transformers, generators, motors, loads, capacitors
  • Undo / redo, zoom, pan, save and open project files

2Load flow

  • Bus voltages, branch flows and losses
  • Flow arrows shown on the diagram
  • Scenarios for what-if comparisons

3Short circuit

  • Fault levels at buses
  • IEC 60909 method
  • Results feed protection studies

4Unbalanced and single-phase

  • Phase-domain studies for unbalanced and single-phase networks
  • Voltage unbalance factor (VUF)
  • Suited to traction and rural supplies

5Protection

  • Overcurrent relay coordination with time-current curves
  • Sequence of operation for a bus or line fault
  • Distance and line differential protection studies

6Motor starting

  • Voltage dip during motor start
  • Results shown on the diagram
  • Flags buses below the limit

7Harmonics

  • Harmonic distortion (THD) by bus
  • Voltage spectrum chart with limit line
  • Harmonic filter sizing

8Transient stability

  • Generator swing and recovery after a disturbance
  • Detailed generator, exciter and governor models
  • Plots and report tables

9Compensation and FACTS

  • Capacitors and reactors
  • STATCOM and SVC
  • Series compensators (TCSC, SSSC)
  • Compensator effect and sizing studies

10Traction link

  • Import a TPS train run as a time-varying load
  • AC or 3 kV DC substations
  • Harmonic source for 6- or 12-pulse rectifiers

11Renewables and storage

  • Solar and wind plants as network sources
  • Grid-connection checks
  • Storage studies

12Reports and export

  • HTML study reports
  • CSV export from every result window
  • Word report export from the earth grid tool

13Contingency and time series

  • N-1 outage runs, including networks with STATCOM and SVC
  • Time-series runs over a load or generation profile

14Earth grid design

  • Grid resistance, ground potential rise, touch and step voltage
  • Checked against tolerable limits (IEEE Std 80 method)
  • 3D view of the grid and rods
  • A screening calculation: have a qualified engineer review it
Short circuit results on the single-line diagram: Ik and peak current at each bus, with a results table
Run Short Circuit Analysis And Protection Grading With A Click Of The Mouse
Harmonic study: THD on the diagram, voltage spectrum, frequency scan and results table
Check Harmonic Distortion Against Your Limits At Every Bus, Right On The Diagram
Distance relay study
Test Distance Relay Zones Against Faults Along The Line
Transient stability
See Whether Your Generators Stay In Step After A Fault
Earth grid design: touch voltage surface, illustrative approximation
Check Touch And Step Voltages For Your Earth Grid Design

Screenshots use an example network with illustrative values. Click an image to enlarge it.

Nodalus Traction Power Simulator
Railway power system studies

Model the line, the substations and the trains, then see what the supply has to deliver. Built for 3 kV DC and 25 kV AC railways.

1Network and substations

  • Substations, feeding arrangements and sections
  • Overhead line and rail impedances
  • Multi-substation chains with shared load

2Capacity studies

  • Single train, two trains and convoys
  • Timetable simulation with several trains and substations
  • Substation loading and voltage along the line

3Train performance

  • Locomotive and wagon data, track profile
  • Speed, gradient and resistance effects
  • Distributed power for long consists

4Railway protection

  • Fault levels along the line
  • Protection settings and reach checks

5Harmonics

  • Harmonic analysis of traction loads
  • Assessment against IEEE 519 limits

6OHTE interference (EMI)

  • Induced voltage on nearby conductors
  • EN 50121-4 and ITU-T references

7Renewable integration

  • Solar supply to traction substations
  • SA Grid Code references

8Reports and data exchange

  • CSV results export
  • Export a run to Nodalus Power Flow
  • Word and chart reports
Locomotive classes tab with traction effort and line current curves
Load Customized Traction Curves
Track profile tab with simulation range, speed zones and gradient chart
Import Track Geometry
Simulate and results tab with voltage, current and power charts and a live readout
Get Results At A Click Of A Button
Potential regeneration tab with regenerative current and power charts for two trains
Check Your Potential To Regen

TPS results depend on the data you enter (track profile, train loading, substation ratings). Check them against your own design standards before relying on them.

How To Buy
Simple Licensing

Download the installer for free. A 7-day trial key and the installer password are issued by Trans Energy Solutions on request; a licence key unlocks the software after that.

Evaluation

Free Trial

Free
Full software, 7 days, on request

Download the installer, then ask us for a trial key and password. Activation needs an internet connection.

  • The full licensed software: every version 1 study, for 7 days
  • Nodalus Power Flow and the Traction Power Simulator in one installer
  • Runs on your own Windows 10 / 11 (64-bit) PC
  • Trial key and password sent on request; the 7 days start when you enter the key
  • One key activates one computer
  • Open-source notices included
Download Installer Request Trial Key
Full Software
Licensed Edition

Nodalus Licence

Custom Quote
Product key and installer password, per computer

All version 1 studies unlocked, for engineers and design firms.

  • Load flow, short circuit, protection, harmonics and stability studies
  • Installed together with the Traction Power Simulator
  • Licences are issued for a fixed term (for example one month or one year); ask us which suits you
  • One key activates one computer
  • HTML reports and CSV export
  • Licence agreement shown at installation
Request A Quote
Organisations

Teams And Sites

Let's Talk
Several computers or sites

Licences are per computer. Tell us how many computers and sites you have and we will put a volume quote together.

  • A volume quote for your number of computers
  • Questions answered by phone or email
Contact Trans Energy Solutions

Prefer to talk? Call +27 10 825 8550 or email Info@transenergy.co.za.

Download

Nodalus installer for Windows

One installer for Nodalus Power Flow and the Traction Power Simulator.

VersionVersion 1
Released30 October 2026
File size300 MB
PlatformWindows 10 / 11, 64-bit
Memory8 GB RAM recommended
Download Nodalus Setup

If Windows shows a "protected your PC" or download warning, check that the file name and publisher are right, then choose More info → Run anyway. Contact us if you are unsure.

Product key and password

The installer is free to download. To use it you need:

  • an installer password
  • a product key, entered in Nodalus Power Flow

Request a 7-day trial key and password, or buy a licence. Both are issued by Trans Energy Solutions. Contact us:

Info@transenergy.co.za
+27 10 825 8550

Installing and using the software is subject to the licence agreement shown during installation. Open-source components are listed in the notices file that comes with the software.

×